All Categories
Variable Area Flowmeters M9 Head

Variable Area Flowmeters M9 Head

  • Metal tube float flowmeter/exquisite workmanship The float flowmeter has a simple structure, reliable operation, small pressure loss, and is available in explosion-proof, jacket insulation, corrosion-resistant and other forms. It is widely used in pharmaceutical, chemical, light industry, petrochemical and other industrial sectors. The standard LZ series metal tube rotor flowmeter consists of a measuring tube and a local indicator.

Whatspp:+86 18912600763
E-mail:sales@beitemeter.com

Detail

Product Introduction

The BTLZ series intelligent metal tube rotor flowmeter has various measurement forms. According to the output form, it is divided into local indication type, remote transmission output type and control alarm type. According to the explosion-proof requirements, it is divided into ordinary type, intrinsically safe type and isolated explosion-proof type.

Its design and production provide installation methods such as bottom in and top out, top in and bottom out, side in and side out, bottom in and side out, and horizontal installation. It can be equipped with 4~20mA remote transmission output (with HART communication), pulse output, upper and lower limit alarm output and other functions. This intelligent signal transmitter has high accuracy and high reliability, and can replace imported instruments of the same type with high cost performance.

Product Features

1. Strong metal structure design

2. Suitable for various industries of gas and liquid measurement

3. New flow shell structure design, it can be used in high temperature environment without increasing components.

4. Special design of conical measuring tube, its measuring range and measuring linear are wider and better.

5. We can offer flange connection, clamp, thread and other process connection modes, which is suitable for most of the factories application requirements.

6. Measuring part materials can be selected: stainless steel, titanium, Hastelloy, PTFE, FEP, etc

Technical parameters

Measuring range Water    16~150000 L/h
Air         0.5~4000 m3/h
LCD display Instantaneous flow
Cumulative flow
Jacket pressure rating 1.5~42MPa Electrical interface M20×1.5、 PG11、 1/2”NPT
Medium temperature Standard :-80℃~+220℃ Overall height Standard type: 250mm
High temperature type 300℃ Protection level IP65 / IP66 / IP67 / IP68
Lined FEP type ≤85℃ Explosion-proof mark Intrinsically safe : ExiaIICT3~6
Flame-proof : ExbdIICT4~6Gb
Ambient temperature -40℃~+120℃ Medium viscosity DN15: ≤30mPa.s
DN25: ≤250mPa.s
DN50~DN150: ≤300mPa.s
Range ratio 10:1 (special type 20:1) Signal output Standard : 4~20mA
Alarm : 1. Two relay outputs
2. One or two-way
Pulse : 0-1KHz
Accuracy 2.5%FS  1.5%FS  1.0%FS Power supply 24VDC±20%
220VAC
lithium battery
Working pressure PN16MPa (Special type 42MPa)
PN10MPa (Special type 25MPa)
Connection method Flange or Threaded

Product size

Standard dimensions and weight

Variable Area Flowmeters M9 Head

Jacketed Dimensions and weight

Variable Area Flowmeters M9 Head1

FEP Liner type Dimensions and weight

Variable Area Flowmeters M9 Head2

Vertical outlet type Dimensions and weight

Variable Area Flowmeters M9 Head3

Side aisles outlet type:Dimensions ,weight and pressure loss

Variable Area Flowmeters M9 Head4

Bottom inlet and side outlet type:Dimensions ,weight and pressure loss

Variable Area Flowmeters M9 Head5

Horizontal mounting type:Dimensions ,weight and pressure loss

Variable Area Flowmeters M9 Head6

Get In Touch