All Categories
Coriolis Mass Flow Meter

Coriolis Mass Flow Meter

  • The Coriolis mass flowmeter is a new type of flow measurement instrument developed by our company based on the Coriolis force principle, which can directly measure the mass flow rate of fluids and the density of media in closed pipelines. A flowmeter consists of two parts: a flow measurement sensor and a signal converter.

Whatspp:+86 18912600763
E-mail:sales@beitemeter.com

Detail

Product Description

Coriolis mass flow meter is a new type flow meter which is designed according to Micro Motion and Coriolis principle.This kind of new flow meter can measure the fluid directly in a sealed pipeline. It consists of two sections: Sensor and Signal Transmitter.

Main Features

  • Unchallengeable performance on liquid mass flow, volume flow, and density measurement
  • Unique design delivers unparalleled measurement sensitivity and stability
  • Guarantees consistent, reliable performance over the widest flow range
  • Designed to minimize process, mounting, and environmental effect

Application scenario

Coriolis Mass Flow Meter
Coriolis Mass Flow Meter1
Coriolis Mass Flow Meter2
Coriolis Mass Flow Meter3
Coriolis Mass Flow Meter4

Application

The mass flow meter can be used in the following fields to meet the requirements of ingredient, mixing processes and commercial measurement.

  • Chemical: containing chemical reaction system
  • Petroleum:  moisture content analysis
  • Lipids: including vegetable oils, animal fats and other oils
  • Pharmaceutical
  • Painting
  • Paper making
  • Textile printing and dyeing
  • Fuel: crude oil, heavy oil, coal slurry, lubricant and other fuels.
  • Food: gas dissolving beverage, health drink and other liquid.
  • Transportation: pipeline liquid measurement.
  • Low temperature fluid, like liquid oxygen and liquid nitrogen, the low temperature up to -200℃
  • High temperature fluid, the maximum temperature up to 300℃
  • High pressure fluid, like slurry flow measurement for oil drilling cementing

Technical Parameters

  • Dimension and Measuring Range

Specification

DN (mm)

Flow range(kg/h)

Zero Stability, kg/h

Rated Pressure (MPa)

NW
(kg)

GW
(kg)

0.2%

0.15%

0.1%

DN3

3

0~96~120

0.018

0.012

0.012

40

8

19

DN6

6

0~540~660

0.099

0.066

0.066

20

12

22

DN8

8

0~960~1200

0.18

0.12

0.12

20

12

23

DN10

10

0~1500~1800

0.27

0.18

0.18

20

11

24

DN15

15

0~3000~4200

0.63

0.42

0.42

20

12

25

DN20

20

0~6000~7800

1.17

0.78

0.78

16

20

34

DN25

25

0~10200~13500

2.025

1.35

1.35

16

21

35

DN32

32

0~18 000~24 000

3.6

2.4

2.4

16

27

45

DN40

40

0~30 000~36 000

5.4

3.6

3.6

12

35

55

DN50

50

0~48 000~60 000

9

6

6

12

40

60

DN80

80

0~120 000~160 000

24

16

16

8

90

150

DN100

100

0~222 000~270 000

40.5

27

27

8

170

245

DN150

150

0~480 000~600 000

90

60

60

6

255

350

  • Accuracy(Liquid) ( With FT-522 Transmitter):

Measurement accuracy: ±0.1% ±(zero stability/measurement value)%
Measurement accuracy: ±0.15% ±(zero stability/measurement value)%
Measurement accuracy: ±0.2% ±(zero stability/measurement value)%
Repeatability: 1/2 measurement accuracy %

  • Density(Liquid) measuring range and accuracy (With FT-522 series transmitter)

Range: 0.3~3.000g/cm3     Accuracy: ±0.002g/cm3

  • Temperature measuring range and accuracy (With FT-522 transmitter):

Temperature measuring range: -200~350℃   Accuracy: ±1℃

  • Ambient temperature: -20℃~60℃
  • Material : The measuring tube SS316L  Housing: SS304
  • Working pressure: 0~4.0MPa
  • Explosion-proof level : Exd (ia) ⅡC T6Gb