All Categories
Insertion Type Thermal Gas Flowmeter

Insertion Type Thermal Gas Flowmeter

  • Thermal gas mass flowmeter is a new type of instrument used to measure and control gas mass flow. It is designed based on the principle of heat diffusion (heat conduction). The instrument uses the constant temperature difference method to accurately measure the gas. It can be used to monitor the flow of air, oxygen, nitrogen, argon, ammonia, hydrocarbon gas, natural gas, coal gas and other gases in industrial sectors such as petroleum, chemical industry, steel, metallurgy, electric power, light industry, medicine, and environmental protection.

Whatspp:+86 18912600763
E-mail:sales@beitemeter.com

Detail

Measurement principle

The sensor part of the thermal gas mass flow meter consists of two reference-grade platinum resistance temperature sensors. When the meter is working, one sensor continuously measures the medium temperature T1; the other sensor self-heats to a temperature higher than the medium temperature T2. It is used to sense the fluid flow rate and is called a velocity sensor. The temperature AT=T2-T1, T2>T1. When fluid flows through, the gas molecules collide with the sensor and take away the heat of T2, causing the temperature of T2 to drop. To keep AT constant, the power supply current of T2 must be increased. The faster the gas flows, the more heat is taken away. There is a fixed functional relationship between the gas flow rate and the increased heat. This is the constant temperature difference principle.

 

Product features

1. No temperature and pressure compensation is required for gas flow measurement. The measurement is convenient and accurate, and the mass flow rate or standard volume flow rate of the gas can be obtained.

2. Wide range ratio, reaching more than 100:1, can be used for gas leak detection, especially in large pipe diameter, low flow rate, large flow range change and ultra-small flow measurement.

3. Good anti-seismic performance, measurement accuracy is not affected by vibration.

Long service life, the sensor has no moving parts and pressure sensing parts, simple installation and convenient maintenance.

4. Fast response speed, small pressure loss and good repeatability.

5. Adopting digital design, overall digital circuit measurement, LCD display is intuitive and clear, and measurement is accurate.

6. Equipped with RS485 communication module or HART protocol, centralized management can be achieved with the host computer.

 

Flow selection table

Diameter (mm) Minimum flow (Nm³/h) Maximum flow (Nm³/h) Diameter (mm) Minimum flow (Nm³/h) Maximum flow rate (Nm³/h)
125 25 2500 1100 1950 195000
150 35 3500 1200 2280 228000
200 65 6500 1300 2680 268000
250 100 10000 1400 3100 310000
300 150 15000 1500 3560 356000
350 200 20000 1600 4050 405000
400 250 25000 1700 4560 456000
450 320 32000 1800 5150 515000
500 400 40000 1900 5750 575000
550 480 48000 2000 6350 635000
600 560 56000 2500 9500 950000
650 680 68000 3000 14000 1400000
700 780 78000 3500 19000 1900000
800 1000 100000 4000 24000 2400000
900 1300 130000 4500 30000 3000000
1000 1600 160000 5000 38000 3800000

Note 1: The flow rate (speed) range in the above flow selection table is for air, oxygen and other near-ideal gases, and varies for other gases. If users need to expand the range, they can negotiate with our company to place an order; users who measure explosive gases such as oxygen and hydrogen should pay attention to safe flow rate and cleanliness.
2: The standard state of the flow rate (speed) in the above flow selection table is 20℃, 101. 325kPa.