LUGB series vortex flowmeter can be used for flow detection and measurement of various gases, liquids and steam.
LUGB series vortex flowmeter can be used with the intelligent flow totalizer produced by our company, and can also be used with the intelligent instruments produced by other instrument manufacturers, with the characteristics of strong versatility.
LUGB series vortex flowmeter is a flow meter that uses piezoelectric crystal as a detection element and outputs a standard signal proportional to the flow rate. The meter can be directly matched with the DDZ-Ⅲ instrument system, or it can be used with a computer and a distributed control system to measure the flow parameters of different media. The meter is based on the detection principle of fluid vortex street. The piezoelectric crystal for detecting vortex street does not contact the medium. The meter has the characteristics of simple structure, good versatility and high stability.
1. High temperature resistance: The sensor measuring probe is encapsulated with a special process, and the high temperature resistance can reach 350℃
2. Strong versatility: Strong versatility, can measure unclean gases and liquids
3. Long service life: The sensitive element is sealed in the probe body, the detection element does not contact the measurement medium, and the service life is long
4. Compensation design: The sensor adopts compensation design to improve the seismic resistance of the instrument
5. Simple structure: Simple structure, no moving parts, high durability
6. Not affected by the medium: Within the specified Reynolds number range, the measurement is not affected by the temperature, pressure, and viscosity of the medium
7. Good safety: The flow meter can be used in explosion-proof occasions, with good safety
8. Wide range ratio: Wide range ratio, up to 10:1, 15:1
Ambient temperature | (-40~55)℃ |
Relative humidity | (5~90)% |
Atmospheric pressure | (86—106)Kpa |
Nominal diameter | (15~1500)mm (insertion structure for greater than 200mm) |
Measuring medium | Liquid, gas, steam |
Nominal pressure | 1.6Mpa 2.5Mpa 4.0Mpa |
Medium temperature | (-40~+350)℃ |
Accuracy | 0.5%FS, 1.0%FS, 1.5%FS, 2.5%FS |
Linearity | ≤±1.5% |
Repeatability | ≤0.5%, ≤1.0% |
Output signal | Voltage pulse |
(4~20)mA DC (two-wire) | |
Power supply | Voltage pulse 12V DC or 24V DC |
Current type 24V DC | |
Intelligent current type 24V DC | |
Intelligent battery type 3.6V DC | |
Load resistance | Upper limit load resistance does not exceed 350Ω |
Body material | 304 stainless steel |
Connection method | (15~300)mm Flange card-mounted structure |
(200~1500)mm Plug-in structure | |
Protection level | IP65, IP67 |
Cable interface | PG10 |
Explosion-proof type | Intrinsically safe type; Flameproof type |
Explosion-proof mark | iaⅡCT6; dIIBT4 |
Nominal diameter | Inner diameter | Snap-on body | ||
Length L | Outer diameter D | Overall height H | ||
15 | 15 | 50 | 88 | 335 |
20 | 20 | 50 | 88 | 335 |
25 | 25 | 50 | 88 | 335 |
32 | 32 | 50 | 88 | 335 |
40 | 39 | 50 | 88 | 335 |
50 | 49 | 70 | 88 | 335 |
65 | 64 | 70 | 105 | 345 |
80 | 79 | 80 | 117 | 365 |
100 | 99 | 80 | 140 | 382 |
125 | 125 | 70 | 168 | 395 |
150 | 149 | 70 | 190 | 425 |
200 | 207 | |||
250 | 259 | |||
300 | 309 |