{"id":5384,"date":"2025-04-29T11:44:55","date_gmt":"2025-04-29T03:44:55","guid":{"rendered":"http:\/\/192.168.1.196:170\/?p=5384"},"modified":"2026-02-10T16:25:10","modified_gmt":"2026-02-10T08:25:10","slug":"heat-meter-ultrasonic-flow-meter","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/ru\/products\/flow-measurement\/ultrasonic-flow-meter\/heat-meter-ultrasonic-flow-meter\/","title":{"rendered":"Heat Meter Ultrasonic Flowmeter"},"content":{"rendered":"<h4>Product Features<\/h4>\n<p>High precision measurement, strong anti-interference ability, good stability.<\/p>\n<p>Protection level reaches IP68, can work in water-immersed and humid environment for a long time (split protection level IP67).<\/p>\n<p>No mechanical rotating parts, no wear, no pressure loss, long service life.<\/p>\n<p>Support RS485 interface, MODBUS communication protocol, support 4-20mA, pulse output and other signal outputs.<\/p>\n<p>&nbsp;<\/p>\n<h4>Technical parameters<\/h4>\n<table width=\"100%\" border=\"1\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Performance<\/td>\n<td width=\"464\" height=\"35\">Parameters<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Nominal diameter<\/td>\n<td width=\"464\" height=\"35\">DN15~DN1000<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Pipe material<\/td>\n<td width=\"464\" height=\"35\">Carbon steel, stainless steel<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Temperature range (\u2103)<\/td>\n<td width=\"464\" height=\"35\">4~160<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Temperature difference range (K)<\/td>\n<td width=\"464\" height=\"35\">3~70 (factory setting minimum temperature difference 0.2)<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Minimum pairing temperature error (\u2103)<\/td>\n<td width=\"464\" height=\"35\">\u00b10.1<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Maximum allowable working pressure (Mpa)<\/td>\n<td width=\"464\" height=\"35\">1.6MPa (Special requirements are required if the range exceeds this range)<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Accuracy<\/td>\n<td width=\"464\" height=\"35\">Grade 2<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Temperature sensor type<\/td>\n<td width=\"464\" height=\"35\">PT100, PT100 with pressure installation<\/td>\n<\/tr>\n<tr>\n<td width=\"67\" rowspan=\"3\">Protection level<\/td>\n<td width=\"104\" height=\"35\">Host<\/td>\n<td width=\"464\" height=\"35\">Wall-mounted host: IP67 &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;Integrated host: IP68<\/td>\n<\/tr>\n<tr>\n<td width=\"104\" height=\"35\">Flow sensor<\/td>\n<td width=\"464\" height=\"35\">IP68<\/td>\n<\/tr>\n<tr>\n<td width=\"104\" height=\"35\">Temperature sensor<\/td>\n<td width=\"464\" height=\"35\">IP68<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Working power supply<\/td>\n<td width=\"464\" height=\"35\">DC8~36V, AC85~264V<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Power consumption<\/td>\n<td width=\"464\" height=\"35\">1.5W<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Working environment<\/td>\n<td width=\"464\" height=\"35\">Temperature: -20~75\u2103\u2103; Humidity\u2264100%(RH)<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Communication and output<\/td>\n<td width=\"464\" height=\"35\">RS485, 4-20mA, cumulative pulse, wireless<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Local display<\/td>\n<td width=\"464\" height=\"35\">Dual-line display of cumulative amount, instantaneous flow and instrument working status<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Display resolution<\/td>\n<td width=\"464\" height=\"35\">Accumulated heat 0.001KW.h; thermal power: 0.0001KW; temperature: 0.001\u2103; temperature difference: 0.0001K<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" colspan=\"2\" rowspan=\"2\">Maximum reading<\/td>\n<td width=\"464\" height=\"35\">Net cumulative flow -9999999~9999999m3<\/td>\n<\/tr>\n<tr>\n<td width=\"464\" height=\"35\">Net accumulated heat 0~9999999KW.h<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Storage temperature (\u2103)<\/td>\n<td width=\"464\" height=\"35\">-20~+60<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Data storage<\/td>\n<td width=\"464\" height=\"35\">Wall-mounted host: SD card timed storage of set parameters and measurement results (optional)<\/td>\n<\/tr>\n<tr>\n<td width=\"171\" height=\"35\" colspan=\"2\">Instrument installation location<\/td>\n<td width=\"464\" height=\"35\">Water supply pipeline, return pipeline<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h4>Host Installation<\/h4>\n<p>1. Split Host<\/p>\n<p>&nbsp;Wall-mounted&nbsp;\u2160Host Installation Instructions<\/p>\n<p><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/c4ca4238a0b923820dcc.png\" title=\"Heat Meter Ultrasonic Flowmeter\" alt=\"Heat Meter Ultrasonic Flowmeter\" \/><\/p>\n<p>The wall-mounted type is used for wall installation and is fixed with 4 \u03c66mm expansion bolts or nails.<\/p>\n<p><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/c81e728d9d4c2f636f06-1.jpg\" title=\"Heat Meter Ultrasonic Flowmeter1\" alt=\"Heat Meter Ultrasonic Flowmeter1\" \/><\/p>\n<p>The rail fixing clip is used for rail installation.<\/p>\n<p><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/eccbc87e4b5ce2fe2830.jpg\" title=\"Heat Meter Ultrasonic Flowmeter2\" alt=\"Heat Meter Ultrasonic Flowmeter2\" \/><\/p>\n<p>Use PCB mounting bracket for rail installation<\/p>\n<p><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/a87ff679a2f3e71d9181.jpg\" title=\"Heat Meter Ultrasonic Flowmeter3\" alt=\"Heat Meter Ultrasonic Flowmeter3\" \/><\/p>\n<p>The wall-mounted host can be installed on the wall, distribution box and explosion-proof box using rail installation.<\/p>\n\n\n<p><strong>Application Scenario<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/88130fd894f5a4c02363.webp\"  class=\"wp-image-6936\" srcset=\"https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/88130fd894f5a4c02363.webp 1000w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/88130fd894f5a4c02363-150x150.webp 150w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/88130fd894f5a4c02363-768x768.webp 768w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/88130fd894f5a4c02363-12x12.webp 12w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" title=\"Heat Meter Ultrasonic Flowmeter4\" alt=\"Heat Meter Ultrasonic Flowmeter4\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/157c6810b476001e04d3.webp\"  class=\"wp-image-6937\" srcset=\"https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/157c6810b476001e04d3.webp 1000w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/157c6810b476001e04d3-150x150.webp 150w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/157c6810b476001e04d3-768x768.webp 768w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/157c6810b476001e04d3-12x12.webp 12w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" title=\"Heat Meter Ultrasonic Flowmeter5\" alt=\"Heat Meter Ultrasonic Flowmeter5\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Product Features High precision measurement, strong anti-interference ability, good stability. Protection level reaches IP68, can work in water-immersed and humid environment for a long time (split protection level IP67). No mechanical rotating parts, no wear, no pressure loss, long service life. Support RS485 interface, MODBUS communication protocol, support 4-20mA, pulse output and other signal outputs. [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5385,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[148],"tags":[],"class_list":["post-5384","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ultrasonic-flow-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts\/5384","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/comments?post=5384"}],"version-history":[{"count":3,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts\/5384\/revisions"}],"predecessor-version":[{"id":6938,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts\/5384\/revisions\/6938"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/media\/5385"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/media?parent=5384"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/categories?post=5384"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/tags?post=5384"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}