{"id":5379,"date":"2025-04-29T11:10:04","date_gmt":"2025-04-29T03:10:04","guid":{"rendered":"http:\/\/192.168.1.196:170\/?p=5379"},"modified":"2026-02-10T16:26:15","modified_gmt":"2026-02-10T08:26:15","slug":"pipeline-ultrasonic-flow-meter","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/ru\/products\/flow-measurement\/ultrasonic-flow-meter\/pipeline-ultrasonic-flow-meter\/","title":{"rendered":"Pipeline Ultrasonic Flow Meter"},"content":{"rendered":"<p><strong>Measurement cycle:<\/strong> 500 ms (2 times per second, 128 sets of data collected per cycle)<br data-filtered=\"filtered\"> Working power supply: isolated DC8-36V or AC85~264V optional Maximum flow rate: 64m\/sl Flow rate resolution 0.001 m\/s)<br data-filtered=\"filtered\"> Display: 2x10 Chinese character backlight display (Chinese and English bilingual optional)<br data-filtered=\"filtered\"> Operation: Magnetic 4-button window operation<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Signal input:<\/strong> 3-way 4~20mA analog input, accuracy 0.1%, can input pressure, liquid level, temperature and other signals<br data-filtered=\"filtered\"><br \/>\n2-way three-wire PT100 platinum resistance<br data-filtered=\"filtered\"><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Signal output:<\/strong><\/p>\n<p>1 isolated RS485 output<br data-filtered=\"filtered\"> 1 isolated OCT (pulse width 6~1000ms programmable, default 200ms)<br data-filtered=\"filtered\"> 1 relay output (pulse width 200rms) <br data-filtered=\"filtered\"> 1 4~20mA output (active\/passive output optional) <br data-filtered=\"filtered\"> 1 bidirectional serial peripheral universal interface, can directly connect multiple external devices in series (such as mass data storage modules, printers, etc.)<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Communication protocol:<\/strong> MODBUS protocol, M-BUS protocol, FUJI extended protocol, and compatible with the communication protocols of similar products of other domestic manufacturers<br data-filtered=\"filtered\"><br \/>\n<strong>Connection method:<\/strong>Flange\/slip joint (sanitary type) optional <br data-filtered=\"filtered\"> <strong>Other functions:<\/strong>Automatically memorize the positive\/negative\/net cumulative flow of the previous 512 days, the previous 128 months, and the previous 10 years, automatically memorize the previous 30 times of on\/off time and flow, and can realize automatic or manual replenishment <br data-filtered=\"filtered\"> Can be read through MODBUS protocol<br data-filtered=\"filtered\"> Software upgrade can be realized through code files sent by E-mail<br data-filtered=\"filtered\"> <strong>Power failure protection:<\/strong>Data will not be lost after 100,000 hours of power failure <br data-filtered=\"filtered\"> <strong>Protection level:<\/strong>IP68<br \/>\n<br data-filtered=\"filtered\"> <strong>Electrical interface:<\/strong>M16x1.5 <br data-filtered=\"filtered\"> <strong>Remarks:<\/strong>For detailed parameters, please refer to the ultrasonic flowmeter selection manual.<\/p>","protected":false},"excerpt":{"rendered":"<p>Measurement cycle: 500 ms (2 times per second, 128 sets of data collected per cycle) Working power supply: isolated DC8-36V or AC85~264V optional Maximum flow rate: 64m\/sl Flow rate resolution 0.001 m\/s) Display: 2&#215;10 Chinese character backlight display (Chinese and English bilingual optional) Operation: Magnetic 4-button window operation &nbsp; Signal input: 3-way 4~20mA analog input, [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5513,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[148],"tags":[],"class_list":["post-5379","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ultrasonic-flow-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts\/5379","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/comments?post=5379"}],"version-history":[{"count":3,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts\/5379\/revisions"}],"predecessor-version":[{"id":5637,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/posts\/5379\/revisions\/5637"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/media\/5513"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/media?parent=5379"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/categories?post=5379"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/ru\/wp-json\/wp\/v2\/tags?post=5379"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}