All Categories
Variable Area Flowmeters With Pressure Gauge

Variable Area Flowmeters With Pressure Gauge

  • BTLZ series intelligent metal tube rotor flowmeter is a variable area flowmeter based on float position measurement. It adopts all-metal structure, small size, small pressure loss, large range ratio (10~20:1), optional transmitter with HART communication function, easy installation and maintenance, etc. It is widely used in various industries in complex and harsh environments, for flow measurement and process control of small flow, low flow rate and various harsh media conditions.

Whatspp:+86 18912600763
E-mail:sales@beitemeter.com

Detail

Product Introduction

The BTLZ series of intelligent metal tube rotor flowmeters have a variety of measurement forms for users to choose from according to different user needs and different occasions; according to the output form, they are divided into local indication type, remote transmission output type, and control alarm type; according to the explosion-proof requirements, they can be divided into three types: ordinary type, intrinsically safe type, and isolated explosion-proof type.

The BTLZ series of intelligent metal tube rotor flowmeters use Honeywell's non-contact and non-hysteresis magnetic sensor to detect magnetic field angle changes, and are equipped with a high-performance MCU, which can realize LCD display: instantaneous flow, cumulative amount, loop current, ambient temperature, damping time, and small signal removal amount. Optional 4~20mA remote transmission output (with HART communication), pulse output, upper and lower limit alarm output and other functions. This type of intelligent signal transmitter has high accuracy and reliability, can replace imported instruments of the same type, and has the characteristics of high cost performance, online parameter calibration, and power-off protection.

The design and production of the BTLZ series intelligent metal tube rotor flowmeter also takes into account the user's process flow requirements. There are installation methods such as bottom-in and top-out installation, top-in and bottom-out installation, side-in and side-out installation, bottom-in and side-out installation, and horizontal installation.

 

Product Features

1. All-metal structure design: The sturdy all-metal structure design is suitable for the measurement of gases and liquids in various industries.

2. Case structure design: The new case structure design can be applied to high temperature environments without adding components.

3. Conical measuring tube: The specially designed conical measuring tube has a wider measurement range and better measurement linearity.

4. Various connection methods: Various process connection methods such as flange, clamp, thread, etc. can be provided, which are suitable for most factory application requirements.

5. Optional materials for measuring part: Stainless steel, titanium, Hastelloy, PTFE, FEP and other materials.

6. Magnetic coupling system: The specially designed magnetic coupling system can significantly improve the measurement accuracy and stability.

 

Technical parameters

Measuring range Water (20℃)  16~150000 l/h
Air (0.1013MPa 20℃)  0.5~4000 m3/h
LCD display Instantaneous flow display value range: 0.000~99999
Cumulative flow display value range: 0.00~99999999
Jacket pressure level 1.5~42MPa Electrical interface M20×1.5, PG11, 1/2”NPT or user-provided specifications
Medium temperature Standard type -80℃~+220℃ Overall height Standard type: 250mm (other installation methods see the relevant table)
High temperature type 300℃ Protection level IP65/IP68
Lined FEP type ≤85℃ Explosion-proof mark Intrinsically safe type: ExiaIICT3~6
Flameproof type: ExbdIICT4~6Gb
Ambient temperature -40℃~+120℃ (no LCD display remote transmission type ≤85℃)  (with LCD display remote transmission type ≤70℃) Medium viscosity DN15: ≤5mPa.s
≤30mPa.s)
DN25: ≤250mPa.s
DN50~DN150: ≤300mPa.s
Range ratio 10:1 (special type 20:1) Output Standard signal: two-wire 4~20mA (with HART communication)
Standard signal: three-wire 0~10mA
Alarm signal: 1. Two-way relay output (limit value 125VAC/0.25A)
2. One or two-way proximity switch (switch requirements according to customer requirements)
Pulse signal output: 0-1KHz isolated output (output level Vpp>4.5V)
Accuracy 2.5 (special type 1.5% or 1.0%) Power supply Standard type: 24VDC±20%
AC type: 220VAC (85~265VAC) (customization required)
Battery type: 3.7@4.4-5.2AH lithium battery, each group can be used (3~12 months) according to different usage conditions, and two groups can be replaced.
Working pressure DN15~DN50  PN16MPa (Special type 42MPa)
DN80~DN150 PN10MPa (Special type 25MPa)
Connection method Standard type: HG20592 flange
Special type: User provides flange standard
Threaded connection type: User specified

 

Product size

Variable Area Flowmeters With Pressure Gauge

Standard dimensions and weight

Variable Area Flowmeters With Pressure Gauge1

Jacket type dimensions and weight

Variable Area Flowmeters With Pressure Gauge2

Lined FEP type dimensions and weight

Variable Area Flowmeters With Pressure Gauge3

Top in and bottom out dimensions and weight

Variable Area Flowmeters With Pressure Gauge4

Side inlet and side outlet type: dimensions, weight and pressure loss

Variable Area Flowmeters With Pressure Gauge5

Bottom inlet and side outlet type: dimensions, weight and pressure loss

Variable Area Flowmeters With Pressure Gauge6

Horizontal installation type: dimensions, weight and pressure loss
Get In Touch