{"id":7475,"date":"2026-04-20T17:19:00","date_gmt":"2026-04-20T09:19:00","guid":{"rendered":"https:\/\/www.inst-tech.net\/?p=7475"},"modified":"2026-04-23T15:35:44","modified_gmt":"2026-04-23T07:35:44","slug":"ld-s-electromagnetic-flowmeter","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/fr\/products\/flow-measurement\/electromagnetic-flowmeter\/ld-s-electromagnetic-flowmeter\/","title":{"rendered":"Compact Electromagnetic Flowmeter"},"content":{"rendered":"<p><strong>Instrument Features<\/strong><\/p>\n<ol>\n<li>1.The sensor employs adaptive variable frequency excitation technology, resulting in fast processing speed, high accuracy, and lower power consumption.<\/li>\n<li>2.It can simultaneously measure the instantaneous flow rate, temperature, and pressure parameters of fluid in a pipeline.<\/li>\n<li>3.It employs multiple ARM Cortex-M4 32-bit processors and a 24-bit ADC data acquisition system, resulting in faster operation.<\/li>\n<li>4.It features fully digital signal processing, strong anti-interference capability, reliable measurement, high accuracy, and a wide flow measurement range.<\/li>\n<li>5.Ultra-low EMI power supply, applicable to a wide range of power supply voltage variations, and excellent EMI immunity.<\/li>\n<li>6.The circuit employs rigid-flex PCB and surface mount technology (SMT) for high reliability.<\/li>\n<li>7.The instrument has self-diagnostic functions such as empty pipe detection, excitation circuit fault detection, and flow alarm.<\/li>\n<\/ol>\n<p><strong>Technical Specifications<\/strong><\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td width=\"189\" height=\"35\">Implementation Standards<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">Electromagnetic flow sensor (JB\/T9248)<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Verification Procedure<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">Electromagnetic Flowmeter (JJG1033)<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Measured Medium<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">Conductive liquid (conductivity not less than 2.0uS\/cm)<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Flowmeter Lining<\/td>\n<td colspan=\"2\" height=\"35\">Polyetheretherketone (PEEK) lining<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Flowmeter Diameter<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">DN6\uff5eDN65<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">DN6\uff5eDN65<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">-0.1MPa\uff5e4.0MPa (without pressure sensor)<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Electrode Material<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">HC, 316L<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Body Material<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">304, 316L<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Pipe Interface<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">Threaded, chuck, flange; other interfaces can be customized upon request<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Measurement Accuracy<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">Flow: \u00b10.5%, Temperature: \u00b10.5\u2103, Pressure: \u00b18kPa<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Pressure and Temperature Range<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">(0\uff5e1.6)MPa, (-40\uff5e+120)\u2103 (range adjustable)<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Output Signal<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">(4\uff5e20)mA (maximum load 500\u03a9)<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Communication Protocol<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">IO-Link, RS-485 (MODBUS-RTU)<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Range Ratio<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">1:150<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Power Supply<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">DC (18\uff5e36)V<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Electrical connection<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">M12-4 pin connector<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">Power consumption<\/td>\n<td colspan=\"2\" width=\"378\" height=\"35\">&lt;5W<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" width=\"189\" height=\"35\">Environmental Conditions<\/td>\n<td width=\"378\" height=\"35\">Ambient Temperature<\/td>\n<td width=\"189\" height=\"35\">-25\u2103\uff5e+75\u2103<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" width=\"378\" height=\"35\">Medium temperature<\/td>\n<td width=\"189\" height=\"35\">Standard type-40\u2103\uff5e+90\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"189\" height=\"35\">High-temperature type-40\u2103\uff5e+125\u2103<\/td>\n<\/tr>\n<tr>\n<td width=\"378\" height=\"35\">Protection rating<\/td>\n<td width=\"189\" height=\"35\">IP67<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><strong>Measurement range<\/strong><\/p>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td>DN6<\/td>\n<td>(0.01\uff5e0.75) m3 \/h<br \/>\n(0.17\uff5e13) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN10<\/td>\n<td>(0.02\uff5e1.5) m3 \/h<br \/>\n(0.33\uff5e25) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN15<\/td>\n<td>(0.035\uff5e5) m3 \/h<br \/>\n(0.58\uff5e83) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN20<\/td>\n<td>(0.04\uff5e6) m 3 \/h<br \/>\n(0.67\uff5e100) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN25<\/td>\n<td>(0.1\uff5e15) m3 \/h<br \/>\n(1.67\uff5e250) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN32<\/td>\n<td>(0.15\uff5e20) m3 \/h<br \/>\n(2.50\uff5e333) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN40<\/td>\n<td>(0.25\uff5e38) m3 \/h<br \/>\n(4.17\uff5e633) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN50<\/td>\n<td>(0.4\uff5e60) m3 \/h<br \/>\n(6.67\uff5e1000) L\/min<\/td>\n<\/tr>\n<tr>\n<td>DN65<\/td>\n<td>(0.5\uff5e75) m3 \/h<br \/>\n(8.33\uff5e1250) L\/min<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Instrument Features 1.The sensor employs adaptive variable frequency excitation technology, resulting in fast processing speed, high accuracy, and lower power consumption. 2.It can simultaneously measure the instantaneous flow rate, temperature, and pressure parameters of fluid in a pipeline. 3.It employs multiple ARM Cortex-M4 32-bit processors and a 24-bit ADC data acquisition system, resulting in faster [&hellip;]<\/p>","protected":false},"author":1,"featured_media":7478,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[145,196],"tags":[],"class_list":["post-7475","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electromagnetic-flowmeter","category-electromagnetic-flow-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts\/7475","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/comments?post=7475"}],"version-history":[{"count":3,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts\/7475\/revisions"}],"predecessor-version":[{"id":7512,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts\/7475\/revisions\/7512"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/media\/7478"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/media?parent=7475"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/categories?post=7475"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/tags?post=7475"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}