{"id":7122,"date":"2026-01-29T13:21:13","date_gmt":"2026-01-29T05:21:13","guid":{"rendered":"https:\/\/www.inst-tech.net\/?p=7122"},"modified":"2026-02-25T16:46:48","modified_gmt":"2026-02-25T08:46:48","slug":"insertable-electromagnetic-flow-meter","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/fr\/products\/flow-measurement\/electromagnetic-flowmeter\/insertable-electromagnetic-flow-meter\/","title":{"rendered":"Insertion Electromagnetic Flow Meter"},"content":{"rendered":"<p><strong>The sensor has the following characteristics:<\/strong><br \/>\n\u25c6 The sensor has no moving parts, a simple structure, and reliable operation.<br \/>\n\u25c6 The insertable structure allows for convenient installation and removal without interrupting the flow under low pressure or pressurized conditions. Therefore, it is very suitable for fluid measurement in existing pipelines and facilitates instrument maintenance and repair.<br \/>\n\u25c6 The measurement accuracy is not affected by changes in physical parameters such as temperature, pressure, density, viscosity, and conductivity (as long as the conductivity is greater than 5\u00b5s\/cm) of the measured medium.<br \/>\n\u25c6 The sensor has almost no pressure loss and extremely low energy consumption.<br \/>\n\u25c6 It has lower manufacturing and installation costs than general electromagnetic flow meters. It is particularly suitable for flow measurement in large and medium-diameter pipelines.<br \/>\n\u25c6 It adopts advanced low-frequency square wave excitation. The zero point is stable, the anti-interference ability is strong, and the operation is reliable.<br \/>\n\u25c6 The flow measurement range is large. The full-scale flow velocity in the measured pipeline can be arbitrarily set from 1m\/s to 10m\/s, and the output signal is linearly related to the flow rate.<br \/>\n\u25c6 The flow meter not only has 0~10mA DC or 4~20mA DC standard current output, but also 1~5kHz frequency output.<br \/>\nDue to the series of advantages of the flow meter (sensor) mentioned above, it has been widely used in chemical, chemical fiber, metallurgy, fertilizer, papermaking, water supply and drainage, sewage treatment and other industrial sectors, as well as in agricultural irrigation water metering for conductive liquid flow measurement and automatic control of production processes.<\/p>\n<p><strong><br \/>\n3. Product Type and Composition<\/strong><\/p>\n<p>The product type is insertable.The sensor is connected to the pipeline via a mounting base, ball valve, compression nut, and positioning screw. The sensor comes in two structural types: measuring tube type and planar electrode type.<br \/>\nThe measuring tube type sensor is suitable for measuring clean media; the planar electrode type is suitable for measuring liquid flow containing other impurities.\n<\/p>\n<p>\n<strong>4. Main Technical Specifications<\/strong><br \/>\n4.1 Suitable for pipe diameters: 200~2000mm; <br \/>\n4.2 Flow velocity measurement range: 0~1 to 0~10m\/s, full scale continuously adjustable within the range of 1~10m\/s. <br \/>\n4.3 Measurement accuracy: \u00b11.5% when full-scale flow velocity &gt; 1m\/s. <br \/>\n4.4 Conductivity of the measured medium: Greater than 50\u03bcs\/cm. <br \/>\n4.5 Working pressure: 1.6Mpa. <br \/>\n4.6 Electrode material: Molybdenum-containing stainless steel 0Cr118Ni12Mo2Ti, Hastelloy C-276, Titanium Ti, etc. <br \/>\n4.7 Measuring tube (measuring head) material: ABS <br \/>\n4.8 Maximum temperature of the measured medium: ABS 60\u2103 <br \/>\n4.9 Enclosure protection rating: Complies with the relevant provisions of GB-08-84 standard IP68. <br \/>\n4.10 Sensor output signal: 0.209mVp-p\/1m\/s. <br \/>\n4.11 Maximum signal transmission distance between sensor and converter: 50m (For special requirements, please contact the manufacturer) <br \/>\n4.12 Flowmeter output signal: DC current: 0~10mA, load resistance 0~1k\u03a9; <br \/>\n4~20mA, load resistance 0~500\u03a9; <br \/>\nSuzhou Better Intelligent Instruments Co., Ltd.  Insertion-type Electromagnetic Flowmeter Installation and Operation Manual <br \/>\nFrequency: 1~5KHz, load resistance 250~1.2k\u03a9. <\/p>","protected":false},"excerpt":{"rendered":"<p>The sensor has the following characteristics: \u25c6 The sensor has no moving parts, a simple structure, and reliable operation. \u25c6 The insertable structure allows for convenient installation and removal without interrupting the flow under low pressure or pressurized conditions. Therefore, it is very suitable for fluid measurement in existing pipelines and facilitates instrument maintenance and [&hellip;]<\/p>","protected":false},"author":1,"featured_media":7123,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[145,196],"tags":[],"class_list":["post-7122","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electromagnetic-flowmeter","category-electromagnetic-flow-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts\/7122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/comments?post=7122"}],"version-history":[{"count":3,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts\/7122\/revisions"}],"predecessor-version":[{"id":7286,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/posts\/7122\/revisions\/7286"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/media\/7123"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/media?parent=7122"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/categories?post=7122"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/fr\/wp-json\/wp\/v2\/tags?post=7122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}