{"id":5692,"date":"2025-04-29T14:26:50","date_gmt":"2025-04-29T06:26:50","guid":{"rendered":"http:\/\/beite.wangluocloud.com\/?p=5692"},"modified":"2026-02-10T15:13:29","modified_gmt":"2026-02-10T07:13:29","slug":"lwgy-series-liquid-turbine-flowmeter","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/es\/products\/flow-measurement\/liquid-turbine-flow-meter\/lwgy-series-liquid-turbine-flowmeter\/","title":{"rendered":"Liquid Turbine Flow Meter"},"content":{"rendered":"<h4>Product Introduction<\/h4>\n<p>The LWY on-site display turbine flow sensor is based on the LWGY basic turbine flow sensor, now battery-powered and equipped with an on-site display. This flowmeter is a new flow measurement instrument, integrating a sensor with display and computing functions, developed using advanced ultra-low-power single-chip microcomputer technology. Compared to traditional turbine flow sensor and secondary instrumentation systems, it offers significant advantages, including compact size, light weight, intuitive and clear display, high reliability, immunity to external power supply influences, lightning resistance, and low overall cost. It can be widely used for liquid flow measurement in the petroleum, chemical, light industry, and food industries. This product offers superior performance, reaching the international advanced level of similar products.<br \/>\nFor information on the flow measurement ranges of various flowmeter diameters, sensor dimensions, installation instructions, and maintenance, please refer to Section 2 of this manual, \"LWGY Basic Turbine Flow Sensor.\" <\/p>\n<p><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/dc063f4164741f45fba1.webp\" title=\"Liquid Turbine Flow Meter\" alt=\"Liquid Turbine Flow Meter\" \/> <\/p>\n<p><strong>Left:<\/strong> Confirm parameter settings and exit submenu; <\/p>\n<p><strong>Down:<\/strong> Factory settings shortcut, downshift, and decrement; <\/p>\n<p><strong>Up:<\/strong> Decrement; <\/p>\n<p><strong>Right:<\/strong> Enter parameter settings.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Converter Parameter Description<\/strong>\u00a0\u00a0Instantaneous Flow Parameter Settings<\/p>\n<table width=\"100%\" border=\"1\" cellspacing=\"0\" >\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Flow Units<\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Options: L\/s\u00a0\u00a0L\/m\u00a0\u00a0L\/h\u00a0\u00a0m3\/s\u00a0\u00a0m3\/m\u00a0\u00a0m3\/h\u00a0\u00a0Nm3\/h\u00a0\u00a0USG\/s\u00a0\u00a0USG\/m\u00a0\u00a0USG\/h\u00a0\u00a0Kg\/s\u00a0\u00a0Kg\/m\u00a0\u00a0Kg\/h\u00a0\u00a0t\/s\u00a0\u00a0t\/m\u00a0\u00a0t\/h <br \/>\nDefault value: m3\/h <br \/>\nDefines the unit of instantaneous flow rate <br \/>\nL (liter), h (hour), t (ton), s (second), m (minute) <\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >How many decimal places are in the flow rate? <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Options: 0\u00a0\u00a01\u00a0\u00a02\u00a0\u00a03\u00a0\u00a0Default value: 1 <br \/>\nDefines the number of decimal places for instantaneous flow rate. <\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Range <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Floating point number: 99999999.00-0.00 m\u00b3\/h, default value: 100.0 m\u00b3\/h <br \/>\nWhen the instantaneous flow rate reaches the range, the converter outputs 20mA. Changing this parameter will affect the current output, high and low alarms, etc. <br \/>\n<strong>Note:<\/strong> When you modify this setting (range), please pay attention to the unit of this parameter (range). You can modify the unit of this parameter (range) as needed. <\/strong><\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Small Signal Cutoff <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Floating Point: 9.90 to 0.00%, Default: 0.0% <br \/>\nThis setting is a percentage of the range <\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >High Alarm <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Floating Point: 99.00 to 1.00%, Default: 90.0% <br \/>\nThis setting is a percentage of the range. For example, if this value is set to 10, it is equivalent to 10% of the range. If the absolute value of the instantaneous flow rate is greater than (range \u00d7 10%), the converter outputs a high alarm signal and the high alarm contact closes. <\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Low Alarm<\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Floating point number: 99.00 to 0.00%, default value: 0.0% <br \/>\nThis setting is a percentage of the range. For example, if this value is set to 10, it is equivalent to 10% of the range. If the absolute value of the instantaneous flow rate is less than (range \u00d7 10%), the converter outputs a low alarm signal and the low alarm contact closes. <\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Damping time <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Floating point number: 30.0 to 0.1, default value: 1 <\/p>\n<\/td>\n<\/tr>\n<\/table>\n<p>&nbsp;<\/p>\n<p ><strong>Total amount settings: Define parameters related to the total amount. <\/strong><\/p>\n<table width=\"100%\" border=\"1\" cellspacing=\"0\" >\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Quantity unit <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Options: L(liter) \u00a0m\u00b2\u00a0\u00a0Nm\u00b3\u00a0\u00a0\u00a0\u00a0USG\u00a0\u00a0Kg\u00a0\u00a0t(ton) , <br \/>\nDefault value: m\u00b2 <br \/>\nDefine quantity unit <\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Quantity decimal places <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Options: 0\u00a0\u00a01\u00a0\u00a02\u00a0\u00a03\u00a0\u00a0Default value: 1 <br \/>\nDefine the number of decimal places for the total amount. <\/p>\n<\/td>\n<\/tr>\n<tr >\n<td width=\"250\" height=\"35\" align=\"left\" >\n<p >Preset total amount <\/p>\n<\/td>\n<td width=\"1502\" height=\"35\" align=\"left\" >\n<p >Options: 99999999.00-0.00 m\u00b3\/h, default: 0.0 m\u00b3\/h <br \/>\nClear the total amount or set the total amount. <\/p>\n<\/td>\n<\/tr>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>Product Introduction The LWY on-site display turbine flow sensor is based on the LWGY basic turbine flow sensor, now battery-powered and equipped with an on-site display. This flowmeter is a new flow measurement instrument, integrating a sensor with display and computing functions, developed using advanced ultra-low-power single-chip microcomputer technology. Compared to traditional turbine flow sensor [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5693,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[174,198],"tags":[],"class_list":["post-5692","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-liquid-turbine-flow-meter","category-liquid-turbine-flow-meter-recommended-products"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/posts\/5692","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/comments?post=5692"}],"version-history":[{"count":2,"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/posts\/5692\/revisions"}],"predecessor-version":[{"id":6998,"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/posts\/5692\/revisions\/6998"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/media\/5693"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/media?parent=5692"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/categories?post=5692"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/es\/wp-json\/wp\/v2\/tags?post=5692"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}