{"id":5346,"date":"2025-04-30T12:27:35","date_gmt":"2025-04-30T04:27:35","guid":{"rendered":"http:\/\/192.168.1.196:170\/?p=5346"},"modified":"2026-02-10T15:07:31","modified_gmt":"2026-02-10T07:07:31","slug":"vortex-flowmeter","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/de\/products\/flow-measurement\/vortex-flowmeter\/vortex-flowmeter\/","title":{"rendered":"Vortex Flowmeter"},"content":{"rendered":"<h4>Principle and structure<\/h4>\n<p>The LUGB vortex flowmeter is a velocity flowmeter designed based on the Karman vortex principle. It is primarily used for measuring the flow of media such as gas, steam, or liquids in industrial pipelines. Depending on the model selected, it can measure the temperature, pressure, instantaneous flow rate, and cumulative flow rate of media in industrial pipelines. It also features pulse output, 4-20mA analog signal output, RS485 communication (Modbus RTU protocol), and GPRS internet access.<\/p>\n<h4>Product Features<\/h4>\n<p>1.High reliability, good stability, simple structure, and easy maintenance;<\/p>\n<p>2. The sensor's output pulse frequency is linearly proportional to the fluid flow rate, with no zero drift and high stability;<\/p>\n<p>3. Various structural options available;<\/p>\n<p>4. Liquid measurement accuracy is \u00b11.0%, and gas measurement accuracy is \u00b11.5%;<\/p>\n<p>5. Energy-saving and low pressure drop;<\/p>\n<p>6. Flexible installation options;<\/p>\n<p>7. Multiple circuit protection methods;<\/p>\n<p>8. High-precision probe and piezoelectric crystal vortex sensor for stable signals;<\/p>\n<h4>Technical parameters<\/h4>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td width=\"27%\" height=\"35\">Ambient temperature<\/td>\n<td width=\"73%\" height=\"35\">(-40\uff5e55)\u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Relative humidity<\/td>\n<td height=\"35\">(5\uff5e90)%<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Atmospheric pressure<\/td>\n<td height=\"35\">(86\u2014106)Kpa<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Nominal diameter<\/td>\n<td height=\"35\">(15\uff5e1500)mm (insertion structure for greater than 200mm)<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Measuring medium<\/td>\n<td height=\"35\">Liquid, gas, steam<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Nominal pressure<\/td>\n<td height=\"35\">1.6Mpa\u00a0 2.5Mpa\u00a0 4.0Mpa<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Medium temperature<\/td>\n<td height=\"35\">(-40\uff5e+350)\u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Accuracy<\/td>\n<td height=\"35\">0.5%FS, 1.0%FS, 1.5%FS, 2.5%FS<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Linearity<\/td>\n<td height=\"35\">\u2264\u00b11.5%<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Repeatability<\/td>\n<td height=\"35\">\u22640.5%, \u22641.0%<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"35\">Output signal<\/td>\n<td height=\"35\">Voltage pulse<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">(4\uff5e20)mA DC (two-wire)<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"4\" height=\"35\">Power supply<\/td>\n<td height=\"35\">Voltage pulse\u00a0 12V DC or 24V DC<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Current type\u00a0 24V DC<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Intelligent current type\u00a0 24V DC<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Intelligent battery type\u00a0 3.6V DC<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Load resistance<\/td>\n<td height=\"35\">Upper limit load resistance does not exceed 350\u03a9<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Body material<\/td>\n<td height=\"35\">304 stainless steel<\/td>\n<\/tr>\n<tr>\n<td rowspan=\"2\" height=\"35\">Connection method<\/td>\n<td height=\"35\">(15\uff5e300)mm\u00a0 Flange card-mounted structure<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">(200\uff5e1500)mm\u00a0 Plug-in structure<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Protection level<\/td>\n<td height=\"35\">IP65,\u00a0 IP67<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Cable interface<\/td>\n<td height=\"35\">PG10<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Explosion-proof type<\/td>\n<td height=\"35\">Intrinsically safe type; Flameproof type<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Explosion-proof mark<\/td>\n<td height=\"35\">ia\u2161CT6; dIIBT4<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Structural dimensions<\/h4>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr class=\"coloe\">\n<td rowspan=\"2\" height=\"35\">Nominal diameter<\/td>\n<td rowspan=\"2\" height=\"35\">Inner diameter<\/td>\n<td colspan=\"3\" height=\"35\">Snap-on body<\/td>\n<\/tr>\n<tr class=\"coloe\">\n<td height=\"35\">Length L<\/td>\n<td height=\"35\">Outer diameter D<\/td>\n<td height=\"35\">Overall height H<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">15<\/td>\n<td height=\"35\">15<\/td>\n<td height=\"35\">50<\/td>\n<td height=\"35\">88<\/td>\n<td height=\"35\">335<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">20<\/td>\n<td height=\"35\">20<\/td>\n<td height=\"35\">50<\/td>\n<td height=\"35\">88<\/td>\n<td height=\"35\">335<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">25<\/td>\n<td height=\"35\">25<\/td>\n<td height=\"35\">50<\/td>\n<td height=\"35\">88<\/td>\n<td height=\"35\">335<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">32<\/td>\n<td height=\"35\">32<\/td>\n<td height=\"35\">50<\/td>\n<td height=\"35\">88<\/td>\n<td height=\"35\">335<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">40<\/td>\n<td height=\"35\">39<\/td>\n<td height=\"35\">50<\/td>\n<td height=\"35\">88<\/td>\n<td height=\"35\">335<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">50<\/td>\n<td height=\"35\">49<\/td>\n<td height=\"35\">70<\/td>\n<td height=\"35\">88<\/td>\n<td height=\"35\">335<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">65<\/td>\n<td height=\"35\">64<\/td>\n<td height=\"35\">70<\/td>\n<td height=\"35\">105<\/td>\n<td height=\"35\">345<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">80<\/td>\n<td height=\"35\">79<\/td>\n<td height=\"35\">80<\/td>\n<td height=\"35\">117<\/td>\n<td height=\"35\">365<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">100<\/td>\n<td height=\"35\">99<\/td>\n<td height=\"35\">80<\/td>\n<td height=\"35\">140<\/td>\n<td height=\"35\">382<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">125<\/td>\n<td height=\"35\">125<\/td>\n<td height=\"35\">70<\/td>\n<td height=\"35\">168<\/td>\n<td height=\"35\">395<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">150<\/td>\n<td height=\"35\">149<\/td>\n<td height=\"35\">70<\/td>\n<td height=\"35\">190<\/td>\n<td height=\"35\">425<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">200<\/td>\n<td height=\"35\">207<\/td>\n<td height=\"35\">\u00a0<\/td>\n<td height=\"35\">\u00a0<\/td>\n<td height=\"35\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">250<\/td>\n<td height=\"35\">259<\/td>\n<td height=\"35\">\u00a0<\/td>\n<td height=\"35\">\u00a0<\/td>\n<td height=\"35\">\u00a0<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">300<\/td>\n<td height=\"35\">309<\/td>\n<td height=\"35\">\u00a0<\/td>\n<td height=\"35\">\u00a0<\/td>\n<td height=\"35\">\u00a0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Installation structure diagram<\/h4>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"\/wp-content\/uploads\/2025\/04\/386fd3e6929099f76252.jpg\" title=\"Vortex Flowmeter\" alt=\"Vortex Flowmeter\" \/><\/p>\n<p style=\"text-align: center;\"><strong style=\"text-align: center;\">Installation structure diagram of insertion flow meter<\/strong><\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" src=\"\/wp-content\/uploads\/2025\/04\/067ce8cf3218f44417db.jpg\" title=\"Vortex Flowmeter1\" alt=\"Vortex Flowmeter1\" \/><\/p>\n<p style=\"text-align: center;\"><strong style=\"text-align: center;\">Flange card-mounted flowmeter installation structure diagram<\/strong><\/p>\n<h4>\u00a0<\/h4>\n<h4>Application Scenario<\/h4>\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"1000\" src=\"https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/e6bcc3ec8d136271e5ce.webp\"  class=\"wp-image-6979\" srcset=\"https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/e6bcc3ec8d136271e5ce.webp 1000w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/e6bcc3ec8d136271e5ce-150x150.webp 150w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/e6bcc3ec8d136271e5ce-768x768.webp 768w, https:\/\/www.inst-tech.net\/wp-content\/uploads\/2025\/04\/e6bcc3ec8d136271e5ce-12x12.webp 12w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" title=\"Vortex Flowmeter2\" alt=\"Vortex Flowmeter2\" \/><\/figure>","protected":false},"excerpt":{"rendered":"<p>Principle and structure The LUGB vortex flowmeter is a velocity flowmeter designed based on the Karman vortex principle. It is primarily used for measuring the flow of media such as gas, steam, or liquids in industrial pipelines. Depending on the model selected, it can measure the temperature, pressure, instantaneous flow rate, and cumulative flow rate [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5487,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[146,197],"tags":[],"class_list":["post-5346","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vortex-flowmeter","category-vortex-flow-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts\/5346","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/comments?post=5346"}],"version-history":[{"count":3,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts\/5346\/revisions"}],"predecessor-version":[{"id":6980,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts\/5346\/revisions\/6980"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/media\/5487"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/media?parent=5346"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/categories?post=5346"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/tags?post=5346"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}