{"id":5235,"date":"2025-04-29T10:58:40","date_gmt":"2025-04-29T02:58:40","guid":{"rendered":"http:\/\/192.168.1.196:170\/?p=5235"},"modified":"2026-02-10T17:19:08","modified_gmt":"2026-02-10T09:19:08","slug":"ultrasonic-level-gauge","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/de\/products\/level-measurement\/ultrasonic-level-gauge\/","title":{"rendered":"Ultrasonic Level Gauge"},"content":{"rendered":"<h4>Product Introduction<\/h4>\n<p>1. Multi-pulse low-voltage multi-point transmitting circuit, double-balance noise suppression multi-point receiving circuit<\/p>\n<p>2. Improve the reliability of the instrument, solve the problem of inaccurate measurement due to uneven level, and greatly enhance the anti-interference ability, and can work stably near the transmission tower of the substation.<\/p>\n<p>3. Automatic power adjustment, gain control, and temperature compensation.<\/p>\n<p>4. Leading detection technology and rich software functions to adapt to various complex environments.<\/p>\n<p>5. Advanced waveform calculation technology to improve the measurement accuracy of the instrument.<\/p>\n<p>6. It has the function of suppressing interference echoes to ensure the authenticity of the measured data.<\/p>\n<p>7. 16-bit D\/A conversion to improve the accuracy and resolution of current output.<\/p>\n<p>8. The sensor is made of tetrafluoroethylene material and can be used in various corrosive occasions.<\/p>\n<p>9. Multiple output forms: programmable relay output, high-precision 4-20mA current output, RS-485 digital communication output Split ultrasonic level probe.<\/p>\n<h4>Product Features<\/h4>\n<ul class=\"zygn\">\n<li><span class=\"jdtg\">Strong anti-interference: upper and lower limit nodes and online output adjustment can be set arbitrarily, with on-site display, analog quantity, switch quantity and RS485 output can be selected, and it is convenient to interface with related facilities. <\/span><\/li>\n<li>Adopt polypropylene waterproof shell: <span class=\"jdnr\">The shell is small and quite strong, with excellent chemical resistance. For inorganic compounds, no matter acid, alkali or salt solution, except for strong oxidizing materials, it has almost no destructive effect on them. It is insoluble in almost all solvents at room temperature. It can be used on general alkanes, hydrocarbons, alcohols, phenols, aldehydes, ketones and other media. <\/span><\/li>\n<li>Characteristics: light weight, no scaling, no pollution to the medium, can be used for installation of pharmaceutical and food industry equipment, easy maintenance.<br \/>\n<h4>Main parameters<\/h4>\n<div class=\"zycc\">Main parameters of integrated ultrasonic level meter<\/div>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td height=\"35\">Range<\/td>\n<td height=\"35\">0-3, 5, 8, 10, 15, 20, 30, 40, 50 100m<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Accuracy<\/td>\n<td height=\"35\">0.25%FS<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Blind area<\/td>\n<td height=\"35\">0.15-0.7m<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Working temperature<\/td>\n<td height=\"35\">-20\u2103-+60\u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Pressure range<\/td>\n<td height=\"35\">-1-16 kg<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Power supply<\/td>\n<td height=\"35\">24VDC, 220VAC<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Output<\/td>\n<td height=\"35\">4-20mA, RS485<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Control<\/td>\n<td height=\"35\">Two-way relay<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Protection level<\/td>\n<td height=\"35\">IP68<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Display mode<\/td>\n<td height=\"35\">12864-dot LCD display<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Main parameters<\/h4>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td height=\"35\">Range<\/td>\n<td height=\"35\">0-3, 5, 8, 10, 15, 20m, 30, 40, 50, 60, 70m<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Accuracy<\/td>\n<td height=\"35\">0.25%FS<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Blind area<\/td>\n<td height=\"35\">0.15-1.2m<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Operating temperature<\/td>\n<td height=\"35\">Transmitter -20\u2103-55\u2103 Sensor -25\u2103-80\u2103<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Pressure range<\/td>\n<td height=\"35\">-1-16 kg<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Power supply<\/td>\n<td height=\"35\">24VDC, 220VAC<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Output<\/td>\n<td height=\"35\">4-20mA, RS485<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Control<\/td>\n<td height=\"35\">Four-way relay<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Protection level<\/td>\n<td height=\"35\">IP68<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Display mode<\/td>\n<td height=\"35\">12864-dot LCD display, corrosion-resistant sensor housing made of tetrafluoroethylene<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Technical indicators<\/h4>\n<table border=\"1\" width=\"100%\">\n<tbody>\n<tr>\n<td height=\"35\">Range<\/td>\n<td height=\"35\">0.3\uff5e5m, 0.3\uff5e8m, 0.5\uff5e12m<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Blind area<\/td>\n<td height=\"35\">&lt;0.3m,&lt;0.5 m<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Emission angle<\/td>\n<td height=\"35\">12\u00b0 Minimum display resolution: 1mm<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Accuracy<\/td>\n<td height=\"35\">\u00b10.3%\u00d7range<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Display<\/td>\n<td height=\"35\">Four-digit eight-segment: 0.5-inch LED<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Operating frequency<\/td>\n<td height=\"35\">20 KHz\uff5e43.0KHz (depending on model specifications)<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">On-site setting<\/td>\n<td height=\"35\">Completed by level meter buttons Calibration: factory calibration, can be calibrated on-site<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Analog output signal<\/td>\n<td height=\"35\">4\uff5e20mA load &gt;300\u03a9; 0\uff5e5V; 1\uff5e5V<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Digital output<\/td>\n<td height=\"35\">RS485 (support Modbus) NPN switch output<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Working voltage<\/td>\n<td height=\"35\">DC12\u201424V Power consumption &lt;1.5W<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Dimensions<\/td>\n<td height=\"35\">\u03a683\u00d7145\u00d7M65<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Shell material<\/td>\n<td height=\"35\">PP<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Weight<\/td>\n<td height=\"35\">272g(5m); 410g(12m)<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Installation method<\/td>\n<td height=\"35\">External straight pipe thread M65\u00d71.5<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Protection level<\/td>\n<td height=\"35\">IP65<\/td>\n<\/tr>\n<tr>\n<td height=\"35\">Temperature<\/td>\n<td height=\"35\">-10\u2103\uff5e60\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>Product Introduction 1. Multi-pulse low-voltage multi-point transmitting circuit, double-balance noise suppression multi-point receiving circuit 2. Improve the reliability of the instrument, solve the problem of inaccurate measurement due to uneven level, and greatly enhance the anti-interference ability, and can work stably near the transmission tower of the substation. 3. Automatic power adjustment, gain control, and [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5236,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[141],"tags":[],"class_list":["post-5235","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-level-measurement"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts\/5235","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/comments?post=5235"}],"version-history":[{"count":3,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts\/5235\/revisions"}],"predecessor-version":[{"id":6668,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/posts\/5235\/revisions\/6668"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/media\/5236"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/media?parent=5235"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/categories?post=5235"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/de\/wp-json\/wp\/v2\/tags?post=5235"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}