{"id":5838,"date":"2025-04-16T13:42:34","date_gmt":"2025-04-16T05:42:34","guid":{"rendered":"http:\/\/beite.wangluocloud.com\/?p=5838"},"modified":"2026-02-10T16:58:05","modified_gmt":"2026-02-10T08:58:05","slug":"orifice-flow-meter","status":"publish","type":"post","link":"https:\/\/www.inst-tech.net\/ar\/products\/flow-measurement\/orifice-flow-meter\/orifice-flow-meter\/","title":{"rendered":"Orifice Flow Meter"},"content":{"rendered":"<h4>Product Introduction<\/h4>\n<p>When the fluid that fills the pipeline flows through the throttling device in the pipeline, the flow beam will form a local contraction at the throttling device of the throttling device, thereby increasing the flow rate and lowering the static pressure. Therefore, a pressure drop, that is, a pressure difference, is generated before and after the throttling device. The greater the flow rate of the medium, the greater the pressure difference generated before and after the throttling device. Therefore, the size of the fluid flow can be measured by measuring the pressure difference. This measurement method is based on the law of conservation and the law of flow continuity.<br \/>\nThe intelligent throttling device (orifice flowmeter) is a new generation of flowmeter that integrates flow, temperature, and pressure detection functions, and can automatically compensate for temperature and pressure. It adopts microcomputer technology and new micro-power consumption technology, with powerful functions, compact structure, simple operation, and easy use.<\/p>\n<h4>Product Features<\/h4>\n<p><span class=\"jdtg\">1. All-metal structure design <\/span>: The sturdy all-metal structure design is suitable for the measurement of gas, liquid, and steam in various industries.<\/p>\n<p>2. Case structure design: The new case structure design can be applied to high temperature environment without adding parts.<\/p>\n<p>3. Measurement: The specially designed throttling device structure has a wider measurement range and better measurement linearity.<\/p>\n<p>4. <span class=\"jdtg\">Various connection methods<\/span>: Various process connection methods such as flanges, clamps, and threads can be provided, which are suitable for most factory application requirements.<\/p>\n<p>5. Optional measurement part materials: Stainless steel, titanium, Hastelloy and other materials.<\/p>\n<p>6. Simple installation: The installation is simpler and can be directly connected to differential pressure transmitters and pressure transmitters.<\/p>\n<h4>Technical parameters<\/h4>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\">\n<tbody>\n<tr>\n<td colspan=\"2\" height=\"35\">Nominal diameter DN(mm)<\/td>\n<td colspan=\"2\" height=\"35\">Flow range<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" height=\"35\"><\/td>\n<td width=\"80\" height=\"35\">Water(m3\/h)<\/td>\n<td width=\"181\" height=\"35\">Air(Nm\u00b3\/h)<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">10<\/td>\n<td width=\"106\" height=\"35\">3\/8\"<\/td>\n<td width=\"80\" height=\"35\">0.08-0.42<\/td>\n<td width=\"181\" height=\"35\">0.8-4<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">15<\/td>\n<td width=\"106\" height=\"35\">1\/2\u201d<\/td>\n<td width=\"80\" height=\"35\">0.18-0.96<\/td>\n<td width=\"181\" height=\"35\">2-9.2<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">20<\/td>\n<td width=\"106\" height=\"35\">3\/4\"<\/td>\n<td width=\"80\" height=\"35\">0.45-2.4<\/td>\n<td width=\"181\" height=\"35\">5-23<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">25<\/td>\n<td width=\"106\" height=\"35\">1\"<\/td>\n<td width=\"80\" height=\"35\">0.8-4.2<\/td>\n<td width=\"181\" height=\"35\">8-40<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">32<\/td>\n<td width=\"106\" height=\"35\">1-1\/4\"<\/td>\n<td width=\"80\" height=\"35\">1.2-6.4<\/td>\n<td width=\"181\" height=\"35\">12-60<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">40<\/td>\n<td width=\"106\" height=\"35\">1-1\/2\"<\/td>\n<td width=\"80\" height=\"35\">1.8-9.4<\/td>\n<td width=\"181\" height=\"35\">18-90<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">50<\/td>\n<td width=\"106\" height=\"35\">2\"<\/td>\n<td width=\"80\" height=\"35\">3.5-18.5<\/td>\n<td width=\"181\" height=\"35\">35-175<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">65<\/td>\n<td width=\"106\" height=\"35\">2-1\/2\u201d<\/td>\n<td width=\"80\" height=\"35\">6-32<\/td>\n<td width=\"181\" height=\"35\">60-300<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">80<\/td>\n<td width=\"106\" height=\"35\">3\"<\/td>\n<td width=\"80\" height=\"35\">8-42<\/td>\n<td width=\"181\" height=\"35\">80-400<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">100<\/td>\n<td width=\"106\" height=\"35\">4\u201d<\/td>\n<td width=\"80\" height=\"35\">16-80<\/td>\n<td width=\"181\" height=\"35\">160-800<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">125<\/td>\n<td width=\"106\" height=\"35\">5\"<\/td>\n<td width=\"80\" height=\"35\">25-125<\/td>\n<td width=\"181\" height=\"35\">250-1250<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">150<\/td>\n<td width=\"106\" height=\"35\">6\"<\/td>\n<td width=\"80\" height=\"35\">35-180<\/td>\n<td width=\"181\" height=\"35\">350-1700<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">200<\/td>\n<td width=\"106\" height=\"35\">8\"<\/td>\n<td width=\"80\" height=\"35\">60-320<\/td>\n<td width=\"181\" height=\"35\">600-2800<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">250<\/td>\n<td width=\"106\" height=\"35\">10\"<\/td>\n<td width=\"80\" height=\"35\">90-480<\/td>\n<td width=\"181\" height=\"35\">900-5000<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">300<\/td>\n<td width=\"106\" height=\"35\">12\"<\/td>\n<td width=\"80\" height=\"35\">160-820<\/td>\n<td width=\"181\" height=\"35\">1600-7800<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">350<\/td>\n<td width=\"106\" height=\"35\">14\"<\/td>\n<td width=\"80\" height=\"35\">200-1000<\/td>\n<td width=\"181\" height=\"35\">2000-9500<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">400<\/td>\n<td width=\"106\" height=\"35\">16\"<\/td>\n<td width=\"80\" height=\"35\">300-1500<\/td>\n<td width=\"181\" height=\"35\">3000-14500<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">450<\/td>\n<td width=\"106\" height=\"35\">18\"<\/td>\n<td width=\"80\" height=\"35\">400-2000<\/td>\n<td width=\"181\" height=\"35\">4000-19000<\/td>\n<\/tr>\n<tr>\n<td width=\"92\" height=\"35\">500<\/td>\n<td width=\"106\" height=\"35\">20\"<\/td>\n<td width=\"80\" height=\"35\">500-2500<\/td>\n<td width=\"181\" height=\"35\">5000-24000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h4>Application<\/h4>\n<div class=\"row pt-20\">\n<div class=\"col-md-4 col-sm-6\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/bf5fb8e97247003f3dfe-1.jpg\" title=\"Orifice Flow Meter\" alt=\"Orifice Flow Meter\" \/><\/div>\n<div class=\"col-md-4 col-sm-6\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/b140addaa4c11975b32c.jpg\" title=\"Orifice Flow Meter1\" alt=\"Orifice Flow Meter1\" \/><\/div>\n<div class=\"col-md-4 col-sm-6\"><img decoding=\"async\" src=\"\/wp-content\/uploads\/2025\/04\/d13d7fd153664f8a7ed0.jpg\" title=\"Orifice Flow Meter2\" alt=\"Orifice Flow Meter2\" \/><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Product Introduction When the fluid that fills the pipeline flows through the throttling device in the pipeline, the flow beam will form a local contraction at the throttling device of the throttling device, thereby increasing the flow rate and lowering the static pressure. Therefore, a pressure drop, that is, a pressure difference, is generated before [&hellip;]<\/p>","protected":false},"author":1,"featured_media":5840,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[183],"tags":[],"class_list":["post-5838","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-orifice-flow-meter"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/posts\/5838","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/comments?post=5838"}],"version-history":[{"count":3,"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/posts\/5838\/revisions"}],"predecessor-version":[{"id":7054,"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/posts\/5838\/revisions\/7054"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/media\/5840"}],"wp:attachment":[{"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/media?parent=5838"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/categories?post=5838"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.inst-tech.net\/ar\/wp-json\/wp\/v2\/tags?post=5838"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}