Overview
This product is manufactured and tested in strict accordance with JG1037-2008 Verification Procedure for Turbine Flow Meters and GB/T21391-2008 National Standard for Measuring Natural Gas with Gas Turbine Flow Meters.
This product has obtained an explosion-proof certificate from the National Explosion-proof Product Quality Supervision Department, explosion-proof mark: ExdlICT6Gb, number: CNEx17.0933.

This series of products is our company's latest research and development of gas turbine flow meters. It integrates advanced concepts from aerospace technology with theories of fluid mechanics and electromagnetics, and is a new generation of high-precision, high-reliability gas precision metering instrument that combines temperature, pressure, and flow sensors with an intelligent flow totalizer. It features excellent low-pressure and high-pressure metering performance, multiple signal output methods, and strong anti-interference capabilities against fluid disturbances. It is widely applicable to the metering of natural gas, coal gas, liquefied petroleum gas, hydrocarbon gases, and other gases. It is combined with modern CNC machining equipment and applies complete and effective process methods.

Our flow meters are rationally structured, durable, repeatable, and easy to install.

Our company provides highly reliable products to our customers. During the R&D phase, in cooperation with bearing manufacturers, we conducted continuous durability tests, exploring the reliability of the bearings and structure. The meter core adopts an integrated design. We provide you with first-class products and first-class reliability assurance, reducing your after-sales burden.

 

Product Features
* High-quality aluminum alloy turbine, with higher flow stabilization and corrosion resistance.
* Imported special bearings, long service life.
* The metering chamber is isolated from the ventilation chamber, ensuring the safety of the instrument.
* It can detect the temperature, pressure, and flow rate of the measured gas, perform automatic flow tracking compensation, and display the cumulative gas volume under standard conditions (P.=101.325kPa, T.=293.15K); real-time temperature and pressure values ​​can be queried.
Wide flow range (Qmax/Qmin≥20:1), good repeatability, and high accuracy (up to grade 1.0). Low pressure loss and low starting flow rate, down to 0.6 m²/h.
Intelligent instrument coefficient with multi-point nonlinear correction.
Built-in pressure and temperature sensors, high safety performance, compact structure, and aesthetically pleasing appearance.
Low power consumption operation; a single 3.6V 10Ah lithium battery can last for more than one year.
Utilizing a new microprocessor and high-performance integrated chip, it boasts high computational accuracy, powerful functions, and superior performance. Employing world-class low-power technology, the overall power consumption is low. It can operate continuously powered by an internal battery or by external power supply.
Our instruments can employ linear correction technology, with up to ten segments of linear correction. This greatly improves the instrument's calculation accuracy.

The flow meter head can rotate 350 degrees for convenient on-site data viewing.

High accuracy, generally reaching ±1.5%, with high precision reaching ±1.0%.

Good repeatability, short-term repeatability can reach 0.05%R~0.2%R. Due to its excellent repeatability, it is the preferred flow meter for trade settlement.

 

Working Principle

When fluid flows into the flow meter, it is rectified and accelerated by the dedicated integrated rectifier at the inlet. Because the turbine blades are at a certain angle to the fluid flow direction, the turbine generates rotational torque. After overcoming frictional torque and fluid resistance torque, the turbine begins to rotate. Within a certain flow range, the angular velocity of the turbine rotation is directly proportional to the fluid volumetric flow rate. Based on the principle of electromagnetic induction, a pulse signal proportional to the fluid volumetric flow rate is induced from a coaxially rotating signal wheel using a magnetic sensor. This signal is amplified, filtered, and shaped, and then fed together with signals from temperature and pressure sensors into the microprocessor unit of the intelligent flow totalizer for calculation and processing. The gas volumetric flow rate and total volume are then directly displayed on the LCD screen.

 

Technical Specifications:
4.1 D/B Type Basic Technical Specifications

4.1.1 D/B Type Measuring Range

Caliber

Flow range m³/h

Caliber

Flow range m³/h

Accuracy

DN25

5~50

DN100

32~650

 

1.0%

1.5%

DN40

7~70

DN150

80~1600

DN50

10~100

DN200

125~2500

DN65

13~250

DN250

200~4000

DN80

20~400

DN300

320~6500

 

4.1.2 Accuracy Class: 1.0 class 1.5 class

4.1.3 Operating Conditions:

Ambient Temperature: -30℃~+60℃; Atmospheric Pressure: 86kPa~106kPa;

Medium Temperature: -20℃~+80℃; Relative Humidity: 5%~95%

 

4.1.4 Electrical Performance Indicators:

Model Specifications

Display and Output Methods

Power Supply

Type D/Type B

Compensation Method: Temperature and pressure compensation, automatically compensating and correcting flow rates under different conditions.

Display: Simultaneously displays temperature, pressure, battery level, cumulative flow, standard instantaneous flow, and operating instantaneous flow.

Intelligent Self-Diagnosis: The instrument has a self-diagnostic function

Signal Output: Pulse, Pulse Equivalent, 4-20mA

Communication: RS485 (MODBUS-RTU)

3.6V 10AH Lithium Battery

Or External Power Supply

DC24V

 

4.1.5 Technical Features

Economical, practical, durable, and stylish appearance.
Uses imported military-grade bearings.
Wide measuring range and low starting flow rate.
The main body is made of high-quality aluminum alloy or stainless steel, and the impeller is made of aluminum alloy; corrosion-resistant and impact-resistant. Cast aluminum explosion-proof meter head, which can rotate 350 degrees for easy data viewing.
The built-in rectifier significantly shortens the distance between the preceding and following straight pipe sections.

The factory-installed filter effectively removes impurities, reducing damage to the impeller.

A large LCD screen displays instantaneous and cumulative flow, temperature, pressure, standard conditions, and operating conditions.

It can be used with our IC card controller to enable prepaid functionality (payment before gas use).

It can be used with our intelligent LNG/CNG gas station management system.

 

4.2 F-type Basic Technical Specifications

4.2.1 F-type Measuring Range

Diameter

Flow range m³/h

Diameter

Flow range m³/h

Accuracy

DN25

2~20

 

DN150

50~1000

 

 

 

1.0%
1.5%

5~70

80~1600

 

DN200

80~1600

DN50

6~100

125~2500

10~160

 

DN250

125~2500

DN80

13~250

200~4000

20~400

 

DN300

200~4000

 

DN100

20~400

320~6500

32~650

DN400

500-10000